- Rated Load Current: 10A, 25A, 40A, 50A, 75A, 100A
- Input Current: 6~10mA
- Input Control Range: 6~32VDC
- 4KV Insulation Strength
- Zero-crossing Trigger
- Equipped with Snubber Circuit.
- Operating Voltage: 24~280VAC / 48~480VAC
- Dimension: 103.5(L) x 78.0(W) x 38.0(H) mm
3) Provided with snubber circuit to absorb surges.
4) High over-current resistance, applicable to lamp or motor load switching.
5) High reliability and long service life
T S - 2 25 D A
① ② ③ ④ ⑤ ⑥
|
① T: 3φ3W |
② S: Solid State Relay
|
③ 2: Load 24 ~ 280VAC
4: Load 48 ~ 480VAC
|
④ 25: 25A
|
⑤ D: Input 6 ~ 32VDC
|
⑥ A: AC/Load (zero cross) |
Input Specification | General Specification | ||
Type | TS- DA | Isolation Strength | >100MΩ |
Input Control Range | 6 ~ 32 VDC | I/O Insulation Voltage | 4000Vrms |
Input Current | 6 ~ 10mA | Breakdown voltage | 2500Vrms |
Pick-up Voltage | 6VDC |
Operating/Storage
Temperature
|
-20°C ~ 80°C /
-40°C ~ 100°C
|
Drop-out Voltage | 3VDC | Housing Material | PC+ABS / PBT (UL 94V0) |
Weight | 550g |
Output Specification | |||||
Type | DC to AC | ||||
Model |
210DA
410DA
|
225DA
425DA
|
240DA
440DA
|
250DA
450DA
|
275DA
475DA
|
Rated Load Current | 10A | 25A | 40A | 50A | 75A |
Operating Voltage | 24 ~ 280VAC / 48 ~ 480VAC | ||||
Peak Voltage | 600Vp / 800Vp | ||||
1-cycle Surge Current | 150A | 250A | 400A | 500A | 750A |
Leakage Current | 3mA | 8mA | |||
On-state Voltage Drop | 1.6V / 25°C | ||||
Response Time | ON < 10ms; OFF < 10ms |
CE declaration of conformity